Examers.io
ExamsOrganizationsHow it worksPricingHelp & FAQ
Dell Technologies logo

Dell PowerSwitch Data Center Deploy

Domain 3Objective 3

Outline the Components of UFD POWERSWITCH-DATA-CENTER-DEPLOY Practice Questions (Page 1)

Part of the Link Redundancy domain, which accounts for 20% of the POWERSWITCH-DATA-CENTER-DEPLOY exam.

19questions here
4free pages
4concepts
20%of the exam

Questions 1–5

  1. 1application · medium

    A data center architect is designing a top-of-rack (ToR) switch deployment where servers connect to the ToR via two 10GbE links, and the ToR connects upstream to two aggregation switches. The architect wants to ensure that if both upstream links on the ToR fail, the server-facing ports are automatically disabled so the servers' NIC teaming software immediately fails over to the secondary ToR switch. Which UFD component configuration is essential for this behavior?

    Select an answer first
  2. 2application · medium

    A Dell PowerSwitch ToR switch has UFD configured with an uplink-state group. The upstream ports are connected to two different aggregation switches. One aggregation switch is rebooted for maintenance, causing both links to that switch to go down. The other aggregation switch's links remain up. What happens to the downstream ports in the UFD group?

    Select an answer first
  3. 3foundation · easy

    What is the function of the uplink-state group in UFD?

    Select an answer first
  4. 4application · medium

    A data center architect is designing a leaf-spine fabric. Each leaf switch has multiple 100GbE uplinks to the spine layer and connects to servers via 25GbE links. The architect wants to use UFD to ensure that if a leaf switch loses all connectivity to the spine layer, the server-facing ports are disabled to trigger server NIC teaming failover. What is the primary purpose of this UFD configuration?

    Select an answer first
  5. 5expert · medium

    A network architect is comparing UFD to other high-availability mechanisms for a data center ToR deployment. The architect's primary goal is to ensure that servers can fail over to a redundant ToR switch as quickly as possible when the primary ToR loses its uplink connectivity. Which mechanism provides the fastest and most deterministic failover trigger for the servers?

    Select an answer first
Finished these 5 questions?

Review the revealed explanations, or continue through the curriculum.

Free Basic Practice is a study aid with revealable answers — not a scored exam. Examers.io is independent and not affiliated with or endorsed by Dell Technologies. “POWERSWITCH-DATA-CENTER-DEPLOY” is a trademark of its owner, used for identification only.