NIST SP 800-82 ICSSCADA Practice Questions (Page 8)

Part of the Standards and Regulations for Cybersecurity domain, which makes up ~13% of our current practice bank. EC-Council does not publish an official question count, but from its 120-minute exam (~50–80 total, ~7–10 in this domain), expect 1–2 from this objective — we provide 42 practice questions to prepare you well beyond it. (estimate)

42questions here
9free pages
9concepts

Questions 36–40

  1. 36expert · hard

    A mid-sized utility is upgrading its legacy SCADA system. The system must remain available 24/7, and the upgrade cannot cause any downtime. The security architect proposes implementing a new firewall and IDS, but the operations team is concerned about introducing latency. The architect must balance security and operational reliability. Which approach best aligns with NIST SP 800-82 while minimizing risk to availability?

    Select an answer first
  2. 37application · medium

    A power utility is implementing NIST SP 800-82 controls for its substation automation system. The system has a legacy HMI that cannot support modern authentication. The security team wants to add a technical control to reduce the risk of unauthorized access. Which control is most appropriate and aligned with SP 800-82?

    Select an answer first
  3. 38application · medium

    A security analyst is reviewing the threat landscape for a power distribution company. The analyst is concerned about a sophisticated adversary that could target the control system. According to NIST SP 800-82, which characteristic of ICS makes them particularly vulnerable to such adversaries?

    Select an answer first
  4. 39application · medium

    An ICS security analyst is reviewing the network architecture of a natural gas pipeline. The analyst notices that the control center uses a standard IT protocol (e.g., Modbus/TCP) to communicate with remote field devices over a wide area network without any encryption. Which threat is most directly increased by this configuration, according to NIST SP 800-82?

    Select an answer first
  5. 40application · medium

    An engineer is documenting the architecture of a manufacturing plant's control system for a security review. The system includes sensors, actuators, a PLC, and an HMI. According to NIST SP 800-82, which description best represents the basic control loop?

    Select an answer first