Part of the TCP/IP and ICS/SCADA Protocols domain, which makes up ~13% of our current practice bank. EC-Council does not publish an official question count, but from its 120-minute exam (~50–80 total, ~7–10 in this domain), expect 1–2 from this objective — we provide 38 practice questions to prepare you well beyond it. (estimate)
38questions here
8free pages
5concepts
Questions 26–30
- 26
An engineer is reviewing the RFC status of a protocol used in a nuclear plant's safety system. The protocol is defined by an RFC that is currently a Draft Standard. The plant's safety requirements mandate the use of 'mature and stable' protocols. What should the engineer recommend?
Select an answer first - 27
A manufacturing plant uses a mix of legacy and modern devices. The legacy devices use a proprietary protocol that is not RFC-defined, while the modern devices use standard TCP/IP. The plant is expanding and needs to integrate the legacy devices with the new network. What is the most effective approach?
Select an answer first - 28
A control systems engineer is configuring a new remote terminal unit (RTU) that communicates with a master station over a cellular link. The RTU supports both TCP and UDP for its SCADA protocol. The link is subject to intermittent packet loss, and the application does not have built-in retransmission. Which RFC-defined protocol should the engineer choose to ensure reliable data delivery?
Select an answer first - 29
A security analyst is documenting the network protocols used in a water treatment facility. The analyst finds that the facility uses a protocol that is defined by multiple RFCs, and the latest RFC obsoletes an earlier one. The analyst wants to reference the current authoritative specification. What should the analyst do?
Select an answer first - 30
An ICS engineer is designing a network for a water treatment plant. The plant has a mix of legacy serial RTUs and modern IP-enabled PLCs. The engineer needs to ensure that all devices can communicate reliably with the central SCADA system. The network team insists on using UDP for all traffic to reduce overhead. Which approach should the engineer take?
Select an answer first